Related instruments

  • SP-300

    SP-300

    Fast, Sensitive, stable and modular

    SP-300 is a state-of-the-art modular high end potentiostat / galvanostat / FRA with remarkable specifications.

    Channel: single/bipot
    Min current dynamic: +/-100 pA
    Min with LC/ULC option: +/-100 fA
    Max current dynamic: +/-500 mA
    Max with current booster option: +-A30
    Voltage range: -10V to +10V
    with option: -48V to +48V
    EIS: up to 7 MHz

  • SP-240

    SP-240

    Compact and powerful in a portable chassis

    SP-240 is the newest, research grade, value-oriented potentiostat / galvanostat in the Bio-Logic product range offering up to 4 Amps.

    Channel: single
    Min current dynamic: +/-100 pA
    Min with LC/ULC option: +/-100 fA
    Max current dynamic: +/4 A
    Max with current booster option: +/-30 A
    Voltage range: -10 V to +14 V
    with option: -48 V to +48 V
    EIS: up to 7 MHz

  • M470 – SVP

    M470 – SVP

    This technique uses a single wire probe to measure the voltage difference in a solution related to local currents flowing from a corroding or polarized sample. The system includes a positioning system, an electrometer board, an LIA (Lock-In Amplifier) and optionally a pstat/gstat/FRA board, all can be hosted in the control box.

    Scanning Vibrating Electrode Technique.
    Measures local anodic and cathodic currents from a free corroding or polarized sample.

  • SP-200

    SP-200

    Compact and powerful in a portable chassis

    The SP-200 is a fast & sensitive high end potentiostat/galvanostat.

    Channel: single
    Min current dynamic: +/-100 pA
    Min with LC/ULC option: +/-100 fA
    Max current dynamic: +/-500 mA
    Max with current booster option: +/- 500 mA
    Voltage range: -10 V to +10 V
    with option: -10 V to +10 V
    EIS: up to 7 MHz

  • SP-150

    SP-150

    Powerful in a versatile chassis

    The SP-150 is a value oriented reseach grade potentiostat/galvanostat

    Channel: single
    Min current dynamic: +/-20 nA
    Min with LC/ULC option: +/-2 pA
    Max current dynamic: +/-800 mA
    Max with current booster option: +/-100 A
    Voltage range: -20 V to +20 V
    EIS: up to 1 MHz

  • SP-50

    SP-50

    Economical and easy to use

    The SP-50 is an educational Potentiostat/galvanostat

    Channel: single
    Min current dynamic: +/-20 nA
    Max current dynamic: +/-800 mA
    Voltage range: -10 V to +10 V
    EIS: no

  • PG581

    PG581

    Ideal for on-site measurements

    The PG581 is a portable potentiostat/galvanostat

    Channel: single
    Min current dynamic: +/-10 pA
    Max current dynamic: +/-20 mA
    Voltage range: -8 V to +8 V
    EIS: no

  • VMP3

    VMP3

    Multi-Channel & Multi-Users

    The VMP3 is a modular 16 channel potentiostat/galvanostat

    Channel: bipot/multi
    Min current dynamic: +/-20 nA
    Min with LC/ULC option: +/-2 pA
    Max current dynamic: +/-400 mA
    Max with current booster option: +/-100 A
    Voltage range: -20 V to +20 V
    EIS: up to 1 MHz

  • VMP-300

    VMP-300

    A new step in the combination of performance and versatility

    VMP-300 is an ultimate and modular 16 channel potentiostat/galvanostat

     

    Channel: bipot/multi
    Min current dynamic: +/-100 pA
    Min with LC/ULC option: +/-100 fA
    Max current dynamic: +/-500 mA
    Max with current booster option: +/-150 A
    Voltage range: -10 V to +10 V
    with option: -48 V to +48 V
    EIS: up to 7 MHz

  • VSP

    VSP

    Ultimate Electrochemical Workstation

    The VSP is a research grade potentiostat system in a 5-channel modular chassis. This allows the VSP to add additional capability in the way of plug-in “modules”.

    Channel: bipot/multi
    Min current dynamic: +/-20 nA
    Min with LC/ULC option: +/-2 pA
    Max current dynamic: +/-400 mA
    Max with current booster option: +/-100 A
    Voltage range: -20 V to +20 V
    EIS: up to 1 MHz

  • VSP-300

    VSP-300

    Fast, sensitive, stable and modular… a remarkable combination!!!

    VSP-300 is a state-of-the-art high end potentiostat / galvanostat / FRA with remarkable specifications.

    Channel: bipot/multi
    Min current dynamic: +/-100 pA
    Min with LC/ULC option: +/-100 fA
    Max current dynamic: +/-500 mA
    Max with current booster option: +/-40 A
    Voltage range: -10 V to +10 V
    with option: -48V to +48V
    EIS: up to 7 MHz

  • SensorStat

    SensorStat

    Up to 14 channels in a versatile chassis

    The SensorSTAT is a value oriented bipotentiostat/bigalvanostat

    Channel: bipot/multi
    Min current dynamic: +/-10 pA
    Max current dynamic: +/-20 mA
    Voltage range: -8 V to +8 V
    EIS: no

  • HCP-803

    HCP-803

    High current potentiostat dedicated for  supercapacitor and photovolatic cell application

    The HCP-803 is a high current potentiostat capable of producing 80 A with a voltage range of ±3 V.

    Channel: single
    Min current dynamic: +/-20 nA
    Max current dynamic: +/-80 A
    Voltage range: -3 V to +3 V
    EIS: up to 15 kHz

  • M470 – ac/dc-SECM

    M470 – ac/dc-SECM

    The probe used in this technique is a tapered disk ultramicroelectrode. The resolution depends on the size of the electrode. The system is provided with a positioning system, a control box hosting two pstat/gstats/FRA to polarize both the sample and the electrode.

    Alternating and direct current Scanning Electrochemical Microscope.
    Measures the local electrochemical reactivity of a surface using dc current or the impedance of the probe.

  • M470 – ic-SECM

    M470 – ic-SECM

    The SECM probe maintained at a constant distance from the sample. Rough, large, uneven samples can be studied using this mode with dc- or ac-SECM. In addition to an ac/dc-SECM system, it only requires an additional piezo element and two LIAs (Lock-In Amplifier) hosted by the control box.

    Intermittent contact SECM.
    Measures the local reactivity of a surface at a constant distance, instead of constant height.

  • M470 – LEIS

    M470 – LEIS

    The local ac current flowing from the sample under sinusoidal potential modulation and leading to the local impedance of the sample is measured by a bi-electrode probe. The system includes a positioning system, an electrometer board, a pstat/gstat/FRA board, all can be hosted in the control box.

    Localized Electrochemical Impedance Spectroscopy.
    Measures a full impedance graph at a specific point or the spatially resolved impedance at one single frequency of a conducting sample.

  • M470 – ac/dc-SDS

    M470 – ac/dc-SDS

    Two scanning heads are offered in this technique: in the first one the electrolyte flowing in the droplet is renewed. In the second the electrolyte in the droplet is static. The system includes a positioning system, an pstat/gstat/FRA that can be hosted in the control box.

    Alternating and direct current Scanning Droplet System.
    Uses a small droplet as an electrolyte and allows the user to select a small area of the sample and interrogate it using classical dc or ac electrochemistry techniques.

  • M470 – SKP

    M470 – SKP

    Using a metallic probe shielded by a metallic cylinder, the Kelvin potential, also named surface potential difference, related to the work function difference, is measured. The system includes a positioning system, an electrometer board, an LIA (Lock-In Amplifier), all are hosted in the control box.

    Scanning Kelvin Probe.
    Measures the local Kelvin potential, which is related to work function difference between the tip and the sample.

  • M470 – OSP

    M470 – OSP

    The OSP scanning head is used with a bespoke that allows all the various modes of operation to be performed. In addition to topography; transparent films thickness can also be measured. The system includes a positioning system, an OSP head and an OSP board.

    Optical Surface Profiler.
    Measures the topography and roughness of a sample using diffracted light from a laser beam.

  • M370 – dc-SECM

    M370 – dc-SECM

    The probe used in this technique is a tapered disk ultramicroelectrode. The resolution depends on the size of the electrode. The system is provided with a positioning system, two control boxes hosting the two pstat/gstats and the positioning control.

    Direct current Scanning Electrochemical Microscope.
    Measures the local electrochemical reactivity of a surface using dc current.

  • M370 – SVP

    M370 – SVP

    This technique uses a single wire probe to measure the voltage difference in a solution related to local currents flowing from a corroding or polarized sample. The system includes a positioning system, an electrometer board, an LIA (Lock-In Amplifier) and optionally a pstat/gstat, all are hosted in the control boxes.

    Scanning Vibrating Electrode Technique.
    Measures local anodic and cathodic currents from a free corroding or polarized sample.

  • M370 – SKP

    M370 – SKP

    Using a metallic probe shielded by a metallic cylinder, the Kelvin potential, also named surface potential difference, related to the work function difference, is measured. The system includes a positioning system, an electrometer board, an LIA (Lock-In Amplifier), all are hosted in the control box.

    Scanning Kelvin Probe.
    Measures the local Kelvin potential, which is related to work function difference between the tip and the sample.

  • M370 – LEIS

    M370 – LEIS

    Using a bi-electrode probe, the local ac current flowing from the sample under sinusoidal potential modulation and leading to the local impedance of the sample is measured. The system includes a positioning system, an electrometer board, a pstat/gstat/FRA, in two different chassis.

    Localized Electrochemical Impedance Spectroscopy.
    Measures a full impedance graph at a specific point or the spatially resolved impedance at one single frequency of a conducting sample.

  • M370 – dc-SDS

    M370 – dc-SDS

    Two scanning heads are offered in this technique: in the first one the electrolyte flowing in the droplet is renewed. In the second the electrolyte in the droplet is static. The system includes a positioning system, two control boxes hosting the pstat/gstat and the positioning control.

    Alternating and direct current Scanning Droplet System.
    Uses a small droplet as an electrolyte and allows the user to select a small area of the sample and interrogate it using classical dc electrochemistry techniques.

  • M370 – OSP

    M370 – OSP

    The OSP scanning head is used with a bespoke that allows all the various modes of operation to be performed. In addition to topography; transparent films thickness can also be measured. The system includes a positioning system, an OSP head and an OSP board.

    Optical Surface Profiler.
    Measures the topography and roughness of a sample using diffracted light from a laser beam.

  • MTZ-35

    MTZ-35

    Exploring new frontiers of impedance testing

    The Bio-Logic MTZ-35 impedance analyzer has the specifications and features required to address the broad scope of applications in the materials research field.

    Frequency Range: 10 μHz to 35 MHz
    Voltage range DC: ±100 μV to ±10 V
    Voltage range AC: 100 μV to 10 V

    Measurement range
    Inductance: 10 nH to 10 kH
    Capacitance: 1 pF to 1000 μF
    Resistance: 1 mΩ to 500 MΩ
    Basic accuracy: 0.1%

  • HCV-3048 Booster

    HCV-3048 Booster

    Fast and powerful current & voltage external booster for VMP-300 series

    The HCV-3048 is designed for battery stack/pack characterizations. The continuous maximum current of +/-30 A for a single unit can be extended up to +/-120 A by connecting four units in parallel.

    Channel: single
    Min current dynamic: +/-300 mA
    Max current dynamic: +/-30 A
    Voltage range: 0 V to +48 V
    EIS: up to 500 kHz

  • FlexP 0160

    FlexP 0160

    High Power Booster for VMP3 (FlexP 0160)

    The FlexP 0160 is designed for battery stack/pack characterizations. The continuous maximum current of +/-50 A for a single unit can be extended up to +/-200 A by connecting four units in parallel.

    Channel: single
    Min current dynamic: +/-500 mA
    Max current dynamic: +/-50 A
    Voltage range: 1 V to +60 V
    EIS: up to 10 kHz

  • SECM150

    SECM150

    SECM150 sets a new standard for value in SECM research. SECM150 is a compact and value-oriented scanning electrochemical microscope that allows the user to perform local investigation on electrodes in any environment. The SECM150 combines high performance and ease-of-use.

    The new standard for value in SECM research !
    So compact that it fits in a glove box!
    Ultra high resolution <10 nm scanning resolution

  • FlexP 0012

    FlexP 0012

    High Power Booster for VMP3 (FlexP 0012)

    The FlexP 0012 is designed for electrolyzer/fuel cell characterizations. The continuous maximum current of +/-200 A for a single unit can be extended up to +/-400 A by connecting two units in parallel.

    Channel: single
    Min current dynamic: +/-500 mA
    Max current dynamic: +/-200 A
    Voltage range: -3 V to +12 V
    EIS: up to 10 kHz